The LS-308 is a noise rejecting, high-dynamic range microphone to be used as a problem solver in challenging recording situations when isolation is needed but difficult to achieve.
Designed for use in studio, broadcast, and sound reinforcement environments when sources are in very close proximity and isolation of those sources is difficult; for example, a small commentators booth with multiple commentators, or rejecting drums from a guitar amp on a tight stage. The LS-308 is a large-diaphragm condenser microphone featuring 270 degrees of off-axis frequency rejection combined with ultra-high dynamic range. Constructed from high-quality components and outfitted with frequency shaping high and low-cut filters, the LS-308 offers excellent handling capabilities. It includes two different mounting options, a foam windscreen, and a road case.
LS-308 AT A GLANCE
270 DEGREES OF REJECTION
The LS-308 offers 270 degrees of side and rear frequency rejection reducing nearby sound by up to 25dB. The rejection is achieved with Lauten Audios’ unique dual, large-diaphragm pressure gradient transducer element in combination with its specially designed circuit.
CLOSE PROXIMITY ENVIRONMENTS
The LS-308 is intended for use in environments where there are multiple sources in close proximity, for example, small live rooms with multiple musicians playing, close-quarter broadcast commentary, or when the rejection of other instruments or crowds live on-stage or in sound reinforcement is desired.
NO ATTENUATOR NEEDED
The LS-308 does not require pre-attenuation and can handle 135dB+ of SPL. The circuit also allows for an ultra-wide 120db of dynamic range. These features give engineers the ability to capture high dynamic sources and in noisy environments.
INDEPENDENT FILTERS
The Independent, multi-stage, high and low-cut filters help engineers balance recordings at the microphone and aid in successfully capturing the performance reducing the need for mixing. The 2-stage low-cut aids in reducing low-end rumble, muddiness, and proximity effect. The 2-stage high-cut helps tame bright instruments and high frequencies.
SHIPS FULLY ACCESSORIZED
FEATURES AND SPECIFICATIONS
Full 120dB (135dB total) of dynamic range
Wide frequency response
Excellent off-axis sound rejection
Independent 2-stage low & high-cut filters
Internally shock mounted pressure dual-gradient condenser element
Includes, hard mount, windscreen, and hardcase
Type: Side-Address dual-large diaphragm pressure gradient transducer
Polar Patterns: Second-order Cardioid
Circuit: JFET transistor with transformer balanced output
Frequency Range: 20Hz-20KHz
Dynamic Range: 135dB
Impedance: >150 ohms
SPL Handling: >135dB (0.5%THD@1000Hz)
Self-noise Level: <15dB-A
Sensitivity: 10.5mV/Pa -40dBv(0 dB=1V/Pa kHz)
Special Features:
50 & 120Hz low-cut
8 & 10 kHz high-cut filters
Connector: 3-pin XLR
Power Requirement: +48v Phantom power
Weight: Microphone only: 1.25lbs – 0.57kg
w/ swing arm: 1.4lb – 0.64kg
w/ hard mount: 1.5lbs – 0.68kg
w/ case and accessories – 4.6lbs –2.09k
Dimensions (no case): Height: 7.25in (18.4cm)
Width (w/ arm): 2.46in (6.25cm)